Time-out OWA 2010 – Exchange 2010

No registro:

  1. On the Client Access server, sign in by using the Exchange administrator account, and then start Registry Editor (regedit).
  2. In Registry Editor, locate the following registry key: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\MSExchange OWA
  3. On the Edit menu, point to New, and then click DWORD Value. In the details pane, name the new value PublicTimeout.
  4. Right-click the PublicTimeout DWORD value, and then click Modify.
  5. In Edit DWORD Value, under Base, click Decimal.
  6. In the Value Data box, type a value in minutes between 1 and 43,200 for a maximum of 30 days. Click OK.

Via Shell do Exchange:

Use the Shell to set the cookie time-out values for public computers using forms-based authentication

You need to be assigned permissions before you can perform this procedure. To see what permissions you need, see the “Outlook Web App mailbox policies” entry in the Client Access Permissions topic.

This example sets the public computer cookie time-out value.

set-ItemProperty ‘HKLM:\SYSTEM\CurrentControlSet\Services\MSExchange OWA’ -name PublicTimeout -value <amount of time> -type dword
 
You must restart the Forms-Based Authentication service for the changes to take effect. On the Client Access server, go to Start > Administrative Tools > Services. In Services, right-click Microsoft Exchange Forms-Based Authentication service, and then click Restart.

This example lets you view the public computer cookie time-out value.

get-ItemProperty ‘HKLM:\SYSTEM\CurrentControlSet\Services\MSExchange OWA’ -name PublicTimeout

This example sets the private computer cookie time-out value.

set-ItemProperty ‘HKLM:\SYSTEM\CurrentControlSet\Services\MSExchange OWA’ -name PrivateTimeout -value <amount of time> -type dword

 
You must restart the Forms-Based Authentication service for the changes to take effect. On the Client Access server, go to Start > Administrative Tools > Services. In Services, right-click Microsoft Exchange Forms-Based Authentication service and click Restart.

This example lets you view the private computer cookie time-out value.

get-ItemProperty ‘HKLM:\SYSTEM\CurrentControlSet\Services\MSExchange OWA’ -name PrivateTimeout

Deixe uma resposta

Preencha os seus dados abaixo ou clique em um ícone para log in:

Logotipo do WordPress.com

Você está comentando utilizando sua conta WordPress.com. Sair / Alterar )

Imagem do Twitter

Você está comentando utilizando sua conta Twitter. Sair / Alterar )

Foto do Facebook

Você está comentando utilizando sua conta Facebook. Sair / Alterar )

Foto do Google+

Você está comentando utilizando sua conta Google+. Sair / Alterar )

Conectando a %s